Full home battery backup with Sol-Ark 15k and EG4 Powerpro. Full install
Installing Sol-Ark 15k with 5670W solar array and EG4 PowerPro battery.
Double throw switch used to switch power from Grid to Sol-Ark.
Bay Area, CA
mysolareng.com
Timecodes:
00:00 - Intro
00:36 - installing solar panels
02:06 - junction box installation
03:25 - main panel / AC disconnects
04:31 - battery installation
04:55 - wireway installation
05:53 - mounting Sol-Ark
06:48 - installing AC disconnects
09:28 - wiring inverter
11:55 - RSD
13:00 - wiring main panel
14:15 - EG4 & Sol-Ark communication
15:02 - system is ON
Просмотров: 3 984

Видео

I cleaned up solar panels, how much extra production I got?
Просмотров 1,6 тыс.14 дней назад
Testing if it makes sense to pay for solar panels cleanup. In my area (Bay Area, CA) it turns out that it won't pay back if you have normally dusted solar panels.
23 Solar panels with Tesla Powerwall 3. Professionally installed. Full home backup.
Просмотров 1,7 тыс.Месяц назад
9.315 kW solar array with two Tesla Powerwall 3. Timestamps: 00:00 - Intro 00:24 - roof before install 01:02 - installing panels mounts 05:11 - day 1 progress 05:42 - installing solar panels 06:56 - Powerwall mounts 07:29 - hanging Powerwall 07:48 - main panel / subpanels 09:10 - hanging 2nd Powerwall 09:39 - conduits 10:39 - run wires 11:45 - wiring main/subpanel 12:40 - connecting PV wires 13...
Installing 2 Tesla Powerwall 3 with 9.7kW solar. Full home backup.
Просмотров 4,6 тыс.Месяц назад
24 Solar panels 405W each. Two Powerwalls 3 AC output is 23kW and 27kWh capcity. #teslapowerwall #teslaenergy
5 areas to avoid on the roof while installing solar panels.
Просмотров 6272 месяца назад
Just sharing my experience.
Installing racking system for solar panels on composite shingles roof.
Просмотров 1,4 тыс.2 месяца назад
Installing IronRidge XR-100 rails for 24 panels. Rafter locator: amzn.to/3xEr3dF As an Amazon Associate I earn from qualifying purchases.
Installing EV charger with Load Management. 40A charger on 70A service.
Просмотров 5632 месяца назад
Charger installed in a condominium complex. The owner has only a 70A service entrance. With load management, we could install a 40A (7.7kW) EV charger. EV charger: amzn.to/4aVZZVE As an Amazon Associate I earn from qualifying purchases.
Tesla Powerwall 3 with 8.5kW solar panels
Просмотров 15 тыс.2 месяца назад
Installing 21 solar panel on comp shingles roof. With Tesla Powerwall 3. 8.5kW DC 11.5kW AC output with 13.5kWh of capacity. #teslapowerwall #teslaenergy
Installing bollards to protect batteries from impact
Просмотров 1,2 тыс.2 месяца назад
Installing bollards to protect batteries from impact
Portable power station with roof mounted solar panels. 4.4 kW solar array. Ecoflow Delta Pro Ultra
Просмотров 3,7 тыс.2 месяца назад
Portable power station with roof mounted solar panels. 4.4 kW solar array. Ecoflow Delta Pro Ultra
EG4 Power Pro 28.6kWh + Luxpower 12k (EG4 18K). Home battery backup installation.
Просмотров 6 тыс.3 месяца назад
EG4 Power Pro 28.6kWh Luxpower 12k (EG4 18K). Home battery backup installation.
Installation of Iron Ridge knockout tile for clay tile roof.
Просмотров 4513 месяца назад
Installation of Iron Ridge knockout tile for clay tile roof.
EcoFlow DELTA Pro Ultra + Smart Home Panel 2. Installed with 3.2kW solar array
Просмотров 10 тыс.3 месяца назад
EcoFlow DELTA Pro Ultra Smart Home Panel 2. Installed with 3.2kW solar array
Use EV to power the home during power outage. V2L. Ioniq 5 | Ioniq 6 | EV6 | EV9 | GV60 | Kona
Просмотров 1,3 тыс.3 месяца назад
Use EV to power the home during power outage. V2L. Ioniq 5 | Ioniq 6 | EV6 | EV9 | GV60 | Kona
Installing 4 solar panels for Ecoflow Delta Pro
Просмотров 2,9 тыс.4 месяца назад
Installing 4 solar panels for Ecoflow Delta Pro
Solar Kit review 5kW Inverter and 5.12kWh Battery from Calpha
Просмотров 2,1 тыс.4 месяца назад
Solar Kit review 5kW Inverter and 5.12kWh Battery from Calpha
Full home battery backup with solar panels and Tesla Powerwall. 9kW solar array, 27kWh battery
Просмотров 1,4 тыс.4 месяца назад
Full home battery backup with solar panels and Tesla Powerwall. 9kW solar array, 27kWh battery
Solar battery backup for home. Sol-Ark 15k with Stackrack batteries.
Просмотров 3,2 тыс.5 месяцев назад
Solar battery backup for home. Sol-Ark 15k with Stackrack batteries.
Testing LiFePo4 capacity after 3 years of use. Are 4000 cycles realistic?
Просмотров 6 тыс.6 месяцев назад
Testing LiFePo4 capacity after 3 years of use. Are 4000 cycles realistic?
Installing IronRidge Camo end clamp and Contour trim
Просмотров 1,3 тыс.6 месяцев назад
Installing IronRidge Camo end clamp and Contour trim
Will Enphase microinverter work without combiner box? Simplest grid-tie solar system.
Просмотров 4,7 тыс.6 месяцев назад
Will Enphase microinverter work without combiner box? Simplest grid-tie solar system.
Etaker M2000 power station test/review. 240 Split phase system.
Просмотров 1,6 тыс.7 месяцев назад
Etaker M2000 power station test/review. 240 Split phase system.
Solar battery backup system for home. Luxpower 12k, 10 solar panels, 5kWh LFP batteries.
Просмотров 1,2 тыс.7 месяцев назад
Solar battery backup system for home. Luxpower 12k, 10 solar panels, 5kWh LFP batteries.
Luxpower 12k with Stackrack batteries. Sunset for Sol-Ark?
Просмотров 1,7 тыс.8 месяцев назад
Luxpower 12k with Stackrack batteries. Sunset for Sol-Ark?
Full-Home solar battery backup with Sol-ark 15k and Pytes batteries. 4.7kW solar system.
Просмотров 9 тыс.8 месяцев назад
Full-Home solar battery backup with Sol-ark 15k and Pytes batteries. 4.7kW solar system.
Installing 28 Solar panels 9.5kW array. Enphase micro inverters.
Просмотров 14 тыс.8 месяцев назад
Installing 28 Solar panels 9.5kW array. Enphase micro inverters.
Installing Enphase consumption CT sensors when feeding wires are unaccessible.
Просмотров 2,8 тыс.9 месяцев назад
Installing Enphase consumption CT sensors when feeding wires are unaccessible.
Installing Tesla EV hardwired charger. Level 2 charging.
Просмотров 58710 месяцев назад
Installing Tesla EV hardwired charger. Level 2 charging.
How to Fix Enphase PV solar system with dead microinverter step by step
Просмотров 4,1 тыс.11 месяцев назад
How to Fix Enphase PV solar system with dead microinverter step by step
The World's First Arkpax Ark 1800W waterproof power station + Review
Просмотров 1,2 тыс.Год назад
The World's First Arkpax Ark 1800W waterproof power station Review

Комментарии

  • @immrnoidall
    @immrnoidall День назад

    UMMM, Fuse? breaker?

  • @immrnoidall
    @immrnoidall День назад

    Never charge in series, without a your BMS . Then just let it charge. and it will balance.. Additional high amp balancer are cheep. Most BMS only balance in milliamps. It will balance but it could take forever.

  • @gangulp
    @gangulp 2 дня назад

    hello what are your thoughts on using an Automatic transfer switch versus a double throw switch ?

    • @SolarEngineering
      @SolarEngineering День назад

      double throw is more like for servicing system, no ATS needed there

  • @djsmithe
    @djsmithe 3 дня назад

    Great video. Thank you.

  • @user-ke1zr4sl3l
    @user-ke1zr4sl3l 3 дня назад

    Лет ми спик фром май харт

  • @ktylxy1
    @ktylxy1 3 дня назад

    The one "waterproof" is not a fuse. It is an automatic circuit breaker with ignition protector. It should allow to pass 100Amps within 1 hour. And more amps you give to it the faster it will switch off. For example it may switch off at 150A after 2 minutes. So I would say it does not work quite correctly switching off at once at 100A exactly. But at least it works. While fuses must be distroyed at once when they reach 100-110A. Automatic circuit breakers and destroyable fuses max amps are counted in a different way.

  • @MrRichardyc
    @MrRichardyc 3 дня назад

    the install guide listed 1awg wires for the 2 hots and neutral, 4awg for ground, it's ok to use 4awg?

  • @kidmikeygo4603
    @kidmikeygo4603 4 дня назад

    I’m doing a near identical install…question…. Did you ground the DPU inverter? Also, did you ground the entire roof array to the SHP2 which is grounded to main panel?

  • @LordStevie
    @LordStevie 4 дня назад

    Were these installers Tesla employees?

    • @SolarEngineering
      @SolarEngineering 4 дня назад

      @@LordStevie no, it's cerified installers from Solar Engineering.

  • @blackdice42
    @blackdice42 5 дней назад

    amazing, nice work

  • @goolala
    @goolala 5 дней назад

    @SolarEngineering where can I buy the communication/12v wires?

    • @SolarEngineering
      @SolarEngineering 5 дней назад

      nassaunationalcable rsd: 18/2 Unshielded VNTC Tray Cable TC-ER THHN Insulation PVC Jacket 600V E2 comm: Belden 28326AS 18 AWG 4C Shielded

    • @goolala
      @goolala 5 дней назад

      @@SolarEngineering thank you! I thought it has to be 120 ohm for CAN wires

  • @boundary1918
    @boundary1918 6 дней назад

    Гарно зроблено. Є чому повчитися! Дякую! По ингліш акценту одразу видно хто звідки. p.s. Дозволяється одному працювати? p.p.s. Ще додам, що у нас по цінам приблизно. Буду на наступному тижні ставити товаришу. Візьму тільки за роботу, тому собівартість рахую обладнання. Батарейка на 16кВт(48В) буде коштувати приблизно 1500 евро Інвертор Дея трифазна на 12кВт десь 2200Евро Панелі на 15кВт десь 1400 евро Електрика різна(щити, пзіп, автомати все ETI ) з купою проводів десь до 1000 евро Загалом собівартість обладнання вийде не більш ніж 6500евро за все, з підключенням до "зеленого" таріфу. Ну якщо купувати та замовляти це на монтажній конторі то десь до 10 вийде.

  • @jimmybrad156
    @jimmybrad156 6 дней назад

    No ferrules for bare wires?

  • @jimmybrad156
    @jimmybrad156 6 дней назад

    What does the spray paint do?

  • @putrafirst
    @putrafirst 6 дней назад

    sir can this work well? power goes into the inverter then pull the power cable into the mcb on the far right then into the main source a Lvd goes to the 48v relay to trigger the relay Then the AC inverter goes to the relay via hole no Pull the cable from the MCB AC inverter output to the contractor so that the load doesn't pass through the relay then enters it into the ATS source B

  • @putrafirst
    @putrafirst 6 дней назад

    sir can this work well? power goes into the inverter then pull the power cable into the mcb on the far right then into the main source a Lvd goes to the 48v relay to trigger the relay Then the AC inverter goes to the relay via hole no Pull the cable from the MCB AC inverter output to the contractor so that the load doesn't pass through the relay then enters it into the ATS source B

  • @hendersonsobers396
    @hendersonsobers396 6 дней назад

    Great job on the setup. The only thing I don't like is the bus bars in the inverter. I wouldn't use those. Instead I would use the 2 cables per side of the battery (4 in total) because of the amount of amps that inverter can push/pull when operating at max. By using 1 cable per side of the battery (2 in total), you're placing a tremendous amount of amps on a single cable when the inverter is operating at or next max.

  • @mdazizurrahman1675
    @mdazizurrahman1675 7 дней назад

    Can I connect 2 pieces of 550watt solar panel (24volt)with a 12 volt 80ampere lead acid battery?

  • @sharingtheadventure
    @sharingtheadventure 7 дней назад

    Excellent. Thank you.

  • @walkerdarin2003
    @walkerdarin2003 7 дней назад

    my solar company cheaped out and I didn't catch it in the contract. I'm having to wait for the DC expansion PW3. I have just the one PW3 with inverter at the moment. Nothing like waiting for a product that isn't out yet....

    • @LordStevie
      @LordStevie 4 дня назад

      I have two Powerwall 3, but with the inverter only connected in one.

  • @moisesmarrero3426
    @moisesmarrero3426 8 дней назад

    Nais yop buen trabajo

  • @GerardoAguilar-kq3lw
    @GerardoAguilar-kq3lw 8 дней назад

    @SolarEngineering Stupid question but I thought Tesla Power wall 3 was not stackable?

    • @SolarEngineering
      @SolarEngineering 8 дней назад

      correct, we cannot install PW3 in front of PW3. PW2 was stackable and we can install few of them in front of each other (search for images: "powerwall 2 stackable"). Because all of the connection in PW3 under the front cover, we cannot cover it with another PW3.

    • @GerardoAguilar-kq3lw
      @GerardoAguilar-kq3lw 8 дней назад

      @@SolarEngineering I was using the wrong terminology, I was saying stackable but I guess the correct term is scalable. Thank you for replying

  • @JustinKais
    @JustinKais 9 дней назад

    Was hoping you would show more of the breaker wiring instead of the "jack rabbit on a date" video. disappointed

  • @shubhamshinde2120
    @shubhamshinde2120 10 дней назад

    As always awesome videos. can we use one RSD for 4 tesla powerwall batteries? Would love to check your video of 4 powerwall installation.

    • @SolarEngineering
      @SolarEngineering 9 дней назад

      by RSD you mean emergency stop button? If yes, then I only found a button that can fit max 3 contacts.

  • @Ulbre
    @Ulbre 10 дней назад

    I wouldn't have thought that this would work given that the two phases are out of phase with each other. But hey, it worked so well done :) :) :) I will try this on my three phase 230v.

  • @ssoffshore5111
    @ssoffshore5111 10 дней назад

    Very nice, thanks for sharing! One thing I would've done differently would've been to leave some space between the battery and the gutter/inverter. Since that battery was hung on a cleat, everything above it will have to be completely undone if for any reason that battery needs to be removed/replaced.

    • @SolarEngineering
      @SolarEngineering 10 дней назад

      we still need some kind of conduit between the battery and the gutter box to protect the wires. and yes, replace the battery will be challenging

  • @meganwinters5163
    @meganwinters5163 10 дней назад

    Not sure if you or the customer is aware (also not to be rude). That single battery can't supply enough DC amperage to utilize the full potential of the Sol-ark 15k.? Also in the manner that you wired it, an additional jumper wire tying both DC sides together is needed, per the install manual.?! Hope all is well 🙏.

    • @SolarEngineering
      @SolarEngineering 10 дней назад

      Customer is aware of the power limitation for the battery. One battery port is rated for 200A and battery can output 200A as well. If another battery will be installed, then we need to utilize 2 ports (install battery busbars or run another set of wires) reference from Sol-Ark manual: 1.3 Connection Requirements -> 1. AC / DC Connection Requirements thank you for the feedback

    • @meganwinters5163
      @meganwinters5163 10 дней назад

      @@SolarEngineering appreciated 👍. Thank you for sharing and the reply. Gotta love solar!!

  • @ranig2848
    @ranig2848 11 дней назад

    Nice! How does that compare to PowerWall 3? Cost? Capabilities?

  • @Tokyo1991.JL1AJE
    @Tokyo1991.JL1AJE 11 дней назад

    If I understand this correctly, the longer charging time is due to the lower voltage causing a less aggressive charge current as the battery reaches the final voltage, thus the tail current (typically 2-3%) aka the ‘we can stop charging now’ current must be set at a lower percentage (of the initial CC value) in order to achieve near 100% SOC at the lower final voltage? It looks like finding a sweet spot between 6-10Hrs for 0.2C is warranted but at a voltage that is high enough to trigger the internal BMS of multicell battery such as a 4 cell 12.8V 100Ah LiFePo4 unit. If I’m missing something input would be appreciated!

    • @Tokyo1991.JL1AJE
      @Tokyo1991.JL1AJE 11 дней назад

      Just realized that tail current sensing for end of charge can be left as it is. It’s just going to longer to get there. Adjust ‘absorption’ aka CV phase accordingly I would guess.

  • @joshuasisson6816
    @joshuasisson6816 12 дней назад

    Why isn't it a weather rated sealed box?

    • @pederb82
      @pederb82 11 дней назад

      It is, but in places with a lot of humidity in air the water in the air inside the box condensates with temp change. It’s a big enough problem that it’s possible to get devices you install on the enclosure that uses piezoelectric tech to push humidity out. It uses a tiny tiny amount of current but basically dry the air inside to avoid it. It won’t help no matter how much you seal up the box. Simplest and completely fine solution here is drainage holes. :)

  • @tamerwafikmahmoud9851
    @tamerwafikmahmoud9851 12 дней назад

    Thank you very much 😂😂

  • @DeathbyKillerBong
    @DeathbyKillerBong 12 дней назад

    really gilding the lilly on this install

  • @richarda6435
    @richarda6435 12 дней назад

    You mention getting close to 1600 watts with this 2S2P array, but given the Delta Pro 15 amp limitation, it seems you'd only get around 925 watts? I ran the numbers from those specific panels.

  • @fullyelectric
    @fullyelectric 12 дней назад

    @SolarEngineering do you remember the model panels used for the dual poll and emergency grid shutoff ? Also to pass inspection was all the labels placed on the panels? Also what type silicon sealant use?

    • @SolarEngineering
      @SolarEngineering 12 дней назад

      Single throw AC Disconnect: Siemens GNF324 Double throw: DTGNF224NR ChemLink M1 and yes labels added to pass inspection.

  • @cgutowski471
    @cgutowski471 12 дней назад

    Great video. Was that 1awg to 1/0 cooper or aluminum for 100amp. Thought 3awg copper THHN was enough for 100amp.

    • @SolarEngineering
      @SolarEngineering 12 дней назад

      was 4 awg and now 1/0, all copper

    • @cgutowski471
      @cgutowski471 12 дней назад

      @@SolarEngineering wow. According to the ampacity charts for 75° or 90°, 3awg is sufficient. Where do you see 1/0 is needed for 100amp?

  • @samfish6938
    @samfish6938 12 дней назад

    i wonder why jay box is not waterproof i would use different box looks like it needs rubber gasket

    • @SolarEngineering
      @SolarEngineering 12 дней назад

      it's condensation water, need drain holes

    • @ronaldchong
      @ronaldchong День назад

      thanks for the video. not a criticism, just an observation: that's a heck of a lot of money at ground level outside one's home. have there been thefts of these whole home inverters and/or batteries?

  • @1982757
    @1982757 12 дней назад

    This is the second time I have to warn you about your back. Buy or at least lease a hydraulic lift for heavy loads like batteries. You will strain your back muscles or develop disc prolapse if you keep lifting them manually. It is even bad that the lifting technique is not optimal and puts a lot of stress on your back. You are a fine installer and it would be bad if back pain stops you from producing these nice videos. Clean install as usual.

    • @SolarEngineering
      @SolarEngineering 12 дней назад

      tesla dolly is in transit, thank you for your kind words.

  • @52gulfpapa
    @52gulfpapa 13 дней назад

    Why not move the vents so the maximum number of panels can be properly installed. For such an exprnsive imstallation, wouldn't it be the right thing to do?

  • @anispinner
    @anispinner 13 дней назад

    You have some nice music taste

  • @onthelake9554
    @onthelake9554 13 дней назад

    Nice job ! I'll never understand putting equipment like that outside . I know it's rated for it but it just seems like it would have last longer out of the weather .

    • @SolarEngineering
      @SolarEngineering 13 дней назад

      sometimes city restricts indoor installation, so there is not much choice for equipment location.

    • @fullyelectric
      @fullyelectric 12 дней назад

      Some locations requires outdoor mounted equipment, however the equipment should still be protected from direct sun light and all other elements, however that is a manufacture recommendation not required to pass inspection, so i hope in the future it will be required to pass inspection to protect the gear from the elements directly.

  • @scotthall1381
    @scotthall1381 13 дней назад

    Doesn’t this Void Sol Ark Warranty? Since they don’t have a relationship with EG4

    • @onthelake9554
      @onthelake9554 13 дней назад

      Solark is Battery Agnostic .

    • @alexsiniov
      @alexsiniov 13 дней назад

      Inverters are battery agnostic if it meets the specifications for load and supply

    • @punksjutgbd
      @punksjutgbd 12 дней назад

      Confused this with Enphase perhaps?

  • @medeo9813
    @medeo9813 14 дней назад

    Вы не учли устаревание панелей

  • @ricardophelps6323
    @ricardophelps6323 14 дней назад

    Does not surprise me that the Victron was over engineered, a lot of their stuff is. A fuse is to protect the cable & whatever connects to it from a short circuit which will generally be hundreds of amps surging. The worst type of fuse is the one that blows (in this case) at 100A, none of them should blow until around 120A or more.

  • @erikj9962
    @erikj9962 16 дней назад

    Thanks for this video. It confirmed what I already thought. I live in socal and only see a small production benefit after the first rain of winter.

  • @whatsupshittafabraans1926
    @whatsupshittafabraans1926 17 дней назад

    One blow I’m yours baby, continued hitting softens the grip -dude,

  • @DADDYfittTV
    @DADDYfittTV 17 дней назад

    Nice bro

  • @saileshs970
    @saileshs970 17 дней назад

    is AP smart the only RSD compliant device for luxpower inverter?

  • @user-fr6kz3oe5s
    @user-fr6kz3oe5s 18 дней назад

    How many watts is soldering tool ?

  •  18 дней назад

    Grear video! Thank you for your work! How much power can this batery pack deliver continously? How many Amps?

  • @seanj2011
    @seanj2011 18 дней назад

    Can I ask why you used what looks like AWG 4 or 6 for the grid/load?

    • @SolarEngineering
      @SolarEngineering 18 дней назад

      it's a partial backup. Inverter replaced 50A generator. So I'm using 6AWG